CTC Union IPM-4SE Especificaciones Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 26
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
Chapter 3 Configuration and Operation
20
3.11 Application Examples
3.11.1 Point-to-Point with single E1 (port1) and LAN port active.
CO Side: (use the correct MAC address for the remote CPE unit)
gci
srcnet 172.16.1.1 255.255.255.0
ipset 192.168.1.11 255.255.255.0 172.16.1.2
ceschset 1 1 172.16.1.2 00:02:AB:xx:xx:xx
cespwidset 1 1 1
pktsize 1 0
jitterbd 1 1
ceschclkset 1 2
lanset 1 7
csave
CPE Side: (use the correct MAC address for the local CO unit)
gci
srcnet 172.16.1.2 255.255.255.0
ipset 192.168.2.11 255.255.255.0 172.16.1.1
ceschset 1 1 172.16.1.1 00:02:AB:xx:xx:xx
cespwidset 1 1 1
pktsize 1 0
jitterbd 1 1
ceschclkset 1 0
lanset 1 7
csave
3.11.2 Point-to-Point with Single E1 (port 1), Fractional /w CRC4 (nx64, n=8) active.
CO Side: (use the correct MAC address for the remote CPE unit)
gci
srcnet 172.16.1.1 255.255.255.0
ipset 192.168.1.11 255.255.255.0 172.16.1.2
ceschset 1 1 172.16.1.2 00:02:AB:xx:xx:xx
cespwidset 1 1 1
pktsize 1 0
jitterbd 1 1
ceschclkset 1 2
cesfe1mode 1 1
cesfe1crc 1 1
cesfe1tsmap 1 x000001FE
lanset 0
csave
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 26

Comentarios a estos manuales

Sin comentarios