FMUX01A/Plus Fiber Optical Multiplexer With 100M Ethernet 4,8,12,16 Channels E1/T1/FXO/FXS/Datacom
Chapter 1 Introduction 10 1.8 Ordering Information Classification Item Single Hot Swap Optical Link Optical Link Type Dual Hot Swap Optical Link (1
Appendix 100 A.2 Troubleshooting Guide No. Symptom Probable Cause Corrective Actions 1 VT-100 can not login ■Serial cable connection invalid. ■B
Appendix 101 No. Symptom Probable Cause Corrective Actions 6. Device can not be managed ■Networking service management SNMP may be off ■Device IP
Appendix 102 A.3 Rack Mount Installation Guide MLRCoOptiOrEXMgL A LSLWTX OptiLSLWTX CAE1 E1/TTBRL A MLRCoOptiOrEXMgL A LSLW
Chapter 2 Installation 11 Chapter 2 Installation This chapter provides the information needed to install the FMUX01A/Plus. It is important to follo
Chapter 3 Panel Description 12 Chapter 3 Panel Description 3.1 Front Panel (1) Optical 1/2 : LSRON LED Yellow light when the laser is on
Chapter 3 Panel Description 13 3.2 Rear Panel Power Switches : On/Off switch for each power main The FMUX01A/Plus provides three major types o
Chapter 3 Panel Description 14 (d) V.35 tributary card This 4 channel V.35 card, also requires HD68 to 4xMB34F adapter cable to connect to V.35 inte
Chapter 4 Quick Start 15 Chapter 4 Quick Start The FMUX01A/Plus control interface provides two modes of operation. First, a serial console port, f
Chapter 4 Quick Start 16 4.1.2 Console Login The factory default username is 'admin' and password is '1234'
Chapter 4 Quick Start 174.1.4 Equipment Status The screen is divided horizontally, displaying the local unit <Lo> on top and
Chapter 4 Quick Start 18 The following shows the screen after setting service mode "in service" (IS), setting unframed, line code B8ZS and
Chapter 4 Quick Start 19 The menu bar at the bottom of the screen now selects the tributary cards for the remote unit. Use the fu
Chapter 4 Quick Start 20 The following screen shows that T1 and E1 for both local and remote units are in-service and without alarms. The "G&qu
Chapter 4 Quick Start 21 4.1.7 Ethernet Trunk Configuration 4.1.7.1 Introduction The trunk Ethernet refers to the 100Mbps trunk speed within the 155
Chapter 4 Quick Start 22 The Trunk Ethernet Configuration menu is displayed below. There are three options. The first option, General Configuration,
Chapter 4 Quick Start 23 Outband (Mgmt Port) In this scenario, the two ports LAN1 and LAN2 will link to the aggregate channel. The manage
Chapter 4 Quick Start 24 Inband+Outband (Mgmt Port) In this scenario, the two front panel ports, LAN1 and LAN2, connect to the fiber aggr
Chapter 4 Quick Start 25 4.1.8 Profile Management The active changes need to be saved if they are to be used during next power up or reboot. Use [ES
Chapter 4 Quick Start 26 4.1.8.2 Profile Operation The FMUX01A/Plus has three profile locations in non-volatile memory. Profile I and Profile II may
Chapter 5 Operation 27 Chapter 5 Operation This chapter will describe in more detail all the operational menu screens and functions of the FMUX01A/P
Chapter 5 Operation 28 The system has built in self-diagnostic functions that are performed during the booting procedure. The self-diagnostic functi
Chapter 5 Operation 29 5.2 Main Menu Note : Not all terminal emulation programs support the use of function keys. There
LEGAL The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. CTC Union T
Chapter 5 Operation 30 5.3 System Configuration System Configuration the menu includes the following selections. System In
Chapter 5 Operation 31 5.3.1 System Information Configuration The system administrator can key in the System Name with less t
Chapter 5 Operation 32 5.3.2 Device Networking Configuration The system administrator can set the system device IP, subnet mas
Chapter 5 Operation 33 5.3.3 User Account Management FMUX01A/Plus provides three levels of the user groups. Admin :the admi
Chapter 5 Operation 34 The default Auto-Logout Seconds is 0, which means the auto-logout function is disabled. Administrator c
Chapter 5 Operation 35 5.3.4 SNMP Agent Configuration The FMUX01A/Plus can assign four sets of the Manager IP address to send Tr
Chapter 5 Operation 36 5.3.5 Software Upgrade Configuration 5.3.5.1 Remote Server Method FMUX01A/Plus can support System So
Chapter 5 Operation 37 5.3.5.2 Local File Method For Local File source selection : The screen will show the available file s
Chapter 5 Operation 38 5.3.6 Software Upgrade and Reboot Operation This function is used to upgrade the local and/or remote un
Chapter 5 Operation 39 When user executes the Upgrade command item in local or remote side, the display will show the status : "Start upgradin
CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60, Zhouzi St. Neihu, Taipei, 114 Taiwan Phon
Chapter 5 Operation 40 When the unit first boots, the profile selection screen will be displayed. Profile I will load by default without any user in
Chapter 5 Operation 41 5.3.7 Network Time Synchronization The system provides the ability to synchronize time to time server u
Chapter 5 Operation 42 5.3.8 Scheduling Job Management The Scheduling Job Management function provides the automatic timely
Chapter 5 Operation 43 Job Type : Periodic (set a time period to do some scheduled task) One shot (perform a scheduled t
Chapter 5 Operation 44 5.3.9 Networking Service Management The system can turn on or turn off the functions of the SNMP Agent,
Chapter 5 Operation 45 5.3.10 Network Trouble Shooting Operation This function can provide tests to determine whether links to
Chapter 5 Operation 46 When target IP ping succeeds, the display will show the following : When target IP ping fails, the disp
Chapter 5 Operation 47 5.3.11 LCD Login Configuration User can define the 'key combination' login password for the
Chapter 5 Operation 48 5.3.12 Event Management FMUX01A/Plus provides Event Management function which includes Event Class Proce
Chapter 5 Operation 49 5.3.12.1 Event Class Processing Configuration The event class processing configuration function can set
Table of Contents i Table of Contents Chapter 1 Introduction...
Chapter 5 Operation 50 5.3.12.2 Event Alarm Processing Configuration The event alarm processing configuration function can set
Chapter 5 Operation 51 5.3.13 System Profile Management Use 'ESC' to return to the Main Menu, select item "1" and press [F2] to
Chapter 5 Operation 52 5.3.13.2 Profile Operation The FMUX01A/Plus has three profile locations in non-volatile memory. Profile I and Profile II may
Chapter 5 Operation 53 5.4 Tributary Slot Interface Selection There are two ways to configure these tributary cards one is in this screen and the o
Chapter 5 Operation 54 5.4.1 E1 Interface Configuration You can edit E1 Parameters for each channel or all channels of
Chapter 5 Operation 55 [F2] Edit channel screen is shown below : The FMUX01A/Plus has two service modes which can select : O
Chapter 5 Operation 56 5.4.2 V.35 Interface Configuration If the EOC (Embedded Operations Channel) connection is closed, a symbo
Chapter 5 Operation 57 You can set the clock source for TC/RC as well as the polarity of TC and/or RC clock to fit the requirements of different DTE
Chapter 5 Operation 58 5.4.3 T1 (DS1) Interface Configuration If the EOC (Embedded Operations Channel) connection is closed, a s
Chapter 5 Operation 59 5.4.4 FXO/FXS Interface Configuration If the EOC (Embedded Operations Channel) connection is closed, a sy
Table of Contents ii 5.4 Tributary Slot Interface Selection...
Chapter 5 Operation 60 5.5 Optical Interface Parameters Configuration [F2] Edit channel screen is shown below :
Chapter 5 Operation 61 [F4]ALS (Auto Laser Shutdown) : Please refer to the definition of ITU-T G.664, when FMUX01A/Plus detects " LOS " a
Chapter 5 Operation 62 5.6 Trunk Ethernet Parameters Configuration 5.6.1 Introduction The trunk Ethernet refers to the 100Mbps trunk speed within th
Chapter 5 Operation 63 5.6.3 Trunk Ethernet General Parameter Config The Trunk Ethernet Configuration menu is displayed below. There are three optio
Chapter 5 Operation 64 Outband (Mgmt Port) In this scenario, the two ports LAN1 and LAN2 will link to the aggregate channel. The manageme
Chapter 5 Operation 65 Inband+Outband (Mgmt Port) In this scenario, the two front panel ports, LAN1 and LAN2, connect to the fiber aggreg
Chapter 5 Operation 66 The following shows how the Management Modes can be used to secure and isolate the management traffic. In the following sc
Chapter 5 Operation 67 5.6.4 Trunk Ethernet Parameter Config The Trunk Ethernet Parameters Config screen will show the LAN1, LAN2 and SNMP managemen
Chapter 5 Operation 68 5.6.5 Trunk Ethernet Rate Configuration Each of three ports, LAN1, LAN2 and SNMP support individual bandwidth control for ing
Chapter 5 Operation 69 5.7 Data Port Parameter Configuration On the front panel of the FMUX01A/Plus is an RJ-45 port labeled 'RS-232'. Thi
Chapter 1 Introduction 7Chapter 1 Introduction 1.1 Product Description The FMUX01A/Plus is a powerful optical multiplexer which can aggregate up to
Chapter 5 Operation 70 5.8 PM Threshold Configuration This function is used to setup the threshold values that meet the requi
Chapter 5 Operation 71 5.8.1 E1 Interface Threshold Setting You can use the function keys to modify the selected traffic link.
Chapter 5 Operation 72 [F1] Line : LCV : Line Code Violation LES : Line Error Second LSES : Line Several Error Second
Chapter 5 Operation 73 5.8.2 Aggregate Interface Threshold Setting You can use the function keys to modify the selected traf
Chapter 5 Operation 74 5.9 Fault Management Parameters Configuration FMUX01A/Plus provides fault management function by setting
Chapter 5 Operation 75 5.9.2 Power Failure Monitoring Parameter Config This provides the function for power monitoring. When &qu
Chapter 5 Operation 76 5.10.1 External Clock Config User can select OOS or IS to turn on or off the external clock input. If
Chapter 5 Operation 77 5.10.2 External Clock Monitoring If the External Clock Module is found, the EquipStatus will show a
Chapter 5 Operation 78 5.1 OE Protection Switching User can configure the active OE module as either locked or as released.
Chapter 5 Operation 79 Automatic laser shutdown and restart concept The ALS mechanism implemented in FMUX01A/Plus is compliant with ITU Recommendati
Chapter 1 Introduction 8 1.3 Product Features Channel Capacity :4, 8, 12, 16 E1, T1, or data communication service Tributary card types : E1 i
Chapter 5 Operation 80 5.12 Equipment Status Monitoring On the equipment status monitoring screen, the user can get an overall view of the alarm sta
Chapter 5 Operation 81 Local site tributary card setup : System Name: Eq
Chapter 5 Operation 82 Remote site tributary card setup : System Name: E
Chapter 5 Operation 83 5.13 Performance Monitoring The performance monitoring screen will show the valid quarters (15 minute i
Chapter 5 Operation 84 There are five types of PM: 1. CurrQuart (Current 15 minute interval) 2. HistQuart (History Quarter) 3
Chapter 5 Operation 85 5.14 Path Alarm Monitoring This screen shows all of alarm status for all monitored paths. Some diagno
Chapter 5 Operation 86 5.15 Loopback/V.54 Testing For diagnostic purposes, low speed E1 or V.35 data channels and high speed
Chapter 5 Operation 87 5.15.1 Loopback Testing Introduction There are four types of loopback functions for the E1/T1 Module : Tributary Local Loop
Chapter 5 Operation 88 There are three types of loopback functions for the V.35 Module : a. Analog (ANA) Loopback : b. Digital (DIG) Loopback c. R
Chapter 5 Operation 89 Info :function key [F8] If the EOC (embedded operations channel) is broken, such as when running the aggregate remote loopba
Chapter 1 Introduction 9 1.4.3 T1 module Channel Capacity : 4 channels per module Bit Rate : 1.544Mbps ± 32ppm Line Code : B8ZS / AMI Fra
Chapter 5 Operation 90 5.16 PRBS Test The PRBS (pseudo- random binary sequence) pattern is 215-1(unframed). E1, T1 and V.3
Chapter 5 Operation 91 Regarding the PRBS test mode, please refer to the following : One way PRBS test setup : Round trip PRBS
Chapter 5 Operation 92 5.17 Event Browser The Event Browser is used to view all of the alarm events in both current memory and
Chapter 6 LCD Operation 93 Chapter 6. LCD Operating Instructions FMUX01A/Plus provides an easy way to set the configuration, do maintenance, and con
Chapter 6 LCD Operation 94 6.1 LCD Menu Tree Password : _ _ _ _ (Modify Password refer to 5.3.10) ---Tb Config ----E1 [Site/Slot/Ch] ----Fr
Chapter 6 LCD Operation 95 ---Lan Port Conifg [Site][Port] ----Service (IS/OOS) ----AutoNeg (ON/OFF) ----Duplex (Full/Half) ----Speed (1
Chapter 6 LCD Operation 96 ---System ----Profile Operation [Site] ----Profile Id (1/2) ---FM Config ----Pwr Fail Mon Cfg [Site/ PwrID]
Chapter 6 LCD Operation 97 --- PRBS Testing[Site] ---- E1 [Slot/Ch] ----PTGEN (ON/OFF) ----PTANA (ON/OFF) ----PTANA Result (Status :Erro
Chapter 6 LCD Operation 98
Appendix 99 Appendix A.1 External User Interface : Async Serial / RS-232 User VT-100 interface / RS232 interface : Signal Ground connects to