USER MANUAL
FMUX04
Fiber Optical Multiplexer
Standalone / Rack Type
4 Channel Fixed Design
G.703 E1, T1(DS1)
SNMP Manageable (Optional)
FXS Order Wire (Optional)
Vista de pagina 0
1 2 3 4 5 6 ... 61 62

Indice de contenidos

Pagina 1 - USER MANUAL

USER MANUAL FMUX04 Fiber Optical Multiplexer Standalone / Rack Type 4 Channel Fixed Design G.703 E1, T1(DS1) SNMP Manageable (Optional) FXS Order

Pagina 2

Chapter 1: Introduction The following photo (AC model), with graphics, shows the major components which make up the FMUX04 (with the Order Wire and S

Pagina 3

Chapter 1: Introduction 11 1.5 Technical Specifications 1.5.1 E1 Link Ports 4 fixed ports Framing Unframed (transparent) Bit Rate 2.048 Mb/s +/-50

Pagina 4

Chapter 1: Introduction 12 1.5.3 Local Setup and Configuration DIP Switches A switch -12 pole, B switch - 2 pole Console Port local VT-100 terminal

Pagina 5 - Table of Contents

Chapter 1: Introduction 13 1.5.6 Optical Specifications Connector Type ST, SC, FC, LC, MT-RJ or WDM-SC (single fiber) Optical mode Multi-mode or Si

Pagina 6

Chapter 1: Introduction 14 1.5.9 Power supply Voltage (AC source) 100 ~ 240 VAC Voltage (DC range 1) 18 ~ 36 VDC Voltage (DC range 2) 36 ~ 72 VDC

Pagina 7 - Chapter 1. Introduction

Chapter 1: Introduction 1.7 T1(DS1) Signal Structure 1.7.1 T1 link line rate The T1 line operates at a nominal rate of 1.544Mb/s. 1.7.2 T1 link lin

Pagina 8

Chapter 1: Introduction 16 This page left blank intentionally.

Pagina 9

Chapter 2. Installation Chapter 2. Installation 2.1 General The Installation chapter will cover the physical installation of the FMUX04, Standalone/R

Pagina 10 - Chapter 1: Introduction

Chapter 2. Installation 2.4 Mechanical Assembly The FMUX04 is designed for standalone use, but it may be rack mounted as required with an optional mo

Pagina 11

Chapter 2. Installation 2.5 Electrical Installation 2.5.1 Power connection, AC For a model with AC power supply, AC power (100~240VAC) is supplied to

Pagina 13

Chapter 2. Installation 2.6 Rear Panel Connectors The rear panel of the FMUX04 supports the E1 and T1 interface connection, the AC or DC power connect

Pagina 14

Chapter 2. Installation 2.8 Removal/Replacement Procedures 2.8.1 Order Wire Feature Module Removal / Replacement ***CAUTION*** This procedure should

Pagina 15

Chapter 2. Installation 2.8.2 SNMP Feature Removal / Replacement ***CAUTION*** This procedure should only be performed by qualified service personne

Pagina 16

Chapter 3. Operation 23 Chapter 3. Operation 3.1 Introduction This chapter will go into the details of the specific configuration and operation of the

Pagina 17 - Chapter 2. Installation

Chapter 3. Operation 3.3 Terminal Mode Operation 24 A notebook computer has become an invaluable tool of the Systems Engineer. Connection between th

Pagina 18

Chapter 3. Operation 3.5 Configuring in Console Mode The FMUX04 Control Port (labeled Console & Alarm on the front panel) is a console terminal

Pagina 19

Chapter 3. Operation If a password is required to login, please enter the 4 digit password previously set. Please see 3.5.2.1 System Configuration re

Pagina 20

Chapter 3. Operation The display window shows the status for both the local and remote multiplexers. If the optical link is broken, the remote status

Pagina 21

Chapter 3. Operation 3.5.2.1 System Configuration Use the System Configuration menu option to save and load the single user setting, to load the fact

Pagina 22

Chapter 3. Operation Loopback Descriptions * LLB (Optical local loop back) near end (NE) far end (FE) * RLB (Optical Remo

Pagina 23 - Chapter 3. Operation

The information contained in this document is subject to change without prior notice. TRADEMARKS Microsoft is a registered trademark of Microsoft C

Pagina 24

Chapter 3. Operation 3.5.2.3 E1/T1 Configuration LOCAL << E1/T1 Configuration >> 1.

Pagina 25

Chapter 3. Operation * RLB (E1/T1 Remote loop back) near end (NE) far end (FE) This remote loop back will loop the logical chan

Pagina 26

Chapter 3. Operation 3.5.2.5 Alarm Relay The fifth item from the ''Configure System Status' menu is the Alarm Relay Co

Pagina 27

Chapter 3. Operation 3.5.2.7 SNMP Configuration Please refer to Chapter 4 SNMP for the configuration of the SNMP option. 3.5.2.8 Upgrade firmware us

Pagina 28

Chapter 3. Operation Upgrade Procedure Select the upgrade option; "1" upgrade the mainboard firmware, or "2" upgrade the FPGA firm

Pagina 29

Chapter 3. Operation 3.5.3 Display Alarm Record From the main login page, press "3" to display the alarm record. The

Pagina 30

Chapter 3. Operation 3.6 Remote Configuration From the main login page select the second option "2", Remote Login. REMOTE

Pagina 31

Chapter 4. SNMP 37 Chapter 4. SNMP 4.1 General The Simple Network Management Protocol (SNMP) is one of many protocols in the Internet Protocol (IP)

Pagina 32

Chapter 4. SNMP 38 The MIB includes the definitions of relevant managed objects (MIB variables) for the specific node. Various MIB's can be defi

Pagina 33

Chapter 4. SNMP In general, SNMP agents support two types of access rights: Read-only the SNMP agent accepts and processes only SNMP getRequest an

Pagina 34

CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60, Zhouzi St. Neihu, Taipei, 114 Taiwan Phon

Pagina 35

Chapter 4. SNMP 4.6.1 Configure the SNMP Agent From the 'SNMP Configuration' menu select "1", SNMP Agent Configuration.

Pagina 36

Chapter 4. SNMP The manager configuration has the ability to setup access for up to four (4) different management workstations. The community strings

Pagina 37 - Chapter 4. SNMP

Chapter 4. SNMP 4.6.4 Save Configuration and Reboot the SNMP From the 'SNMP Configuration' menu, press "4" to sav

Pagina 38

Chapter 4. SNMP Make sure the TFTP server is running and enter your choice of upgrade item. LOCAL <

Pagina 39

Chapter 4. SNMP CTC Union provides a TFTP utility program that runs standalone in Windows® without any installation. We recommend that you copy the p

Pagina 40

Chapter 4. SNMP 4.7 MIB File A MIB is a "management information base" file that allows network management software understand how to manage

Pagina 41

Chapter 4. SNMP 4.8 Web Based Interface When the FMUX04 is installed with the SNMP option, the unit has the added management features of Telnet, SNMP

Pagina 42

Chapter 4. SNMP 4.8.3 Display System Status The default page shown will be the Display System Status page. Note that the navigation menu is in the fra

Pagina 43

Chapter 4. SNMP 4.8.5 System Configuration The System Configuration page is used to save and load user settings, load default settings, clear the alar

Pagina 44

Chapter 4. SNMP 4.8.7 E1/T1 Configuration The E1/T1 configuration page sets the channel service, line code and termination type for the E1/T1. It also

Pagina 45

Table of Contents i Chapter 1. Introduction...

Pagina 46

Chapter 4. SNMP 4.8.9 Alarm Configuration The Alarm Relay page allows enabling or disabling the alarm relay function. (refer to 3.5.2.5)

Pagina 47

Chapter 4. SNMP 4.8.11 SNMP Setup 4.8.11.1 SNMP Agent Configuration Configures the agent IP, subnet mask and default gateway. (refer to 4.6.1)

Pagina 48

Chapter 4. SNMP 4.8.11.3 TFTP Server Configuration Configures the SNMP card for TFTP upgrade. (refer to 4.6.3) 4.8.11.4 Save Conf

Pagina 49

Chapter 4. SNMP 4.8.11.5 TFTP and Upgrade Firmware Once TFTP is properly configured, this page is used to execute the upgrade for SNMP, mainboard firm

Pagina 50

Chapter 4. SNMP 4.8.13 Display Information The Display Information page is where the current versions for main firmware, FPGA and SNMP can be displaye

Pagina 51

Chapter 4. SNMP 55 Set IP login Password The above examples are Telnet using Windows HyperTerminal utility. The scr

Pagina 52

Appendix A. Miscellaneous Appendix A. Miscellaneous A.1 Console port pin assignment The console port on the FMUX04 serves two purposes; it provides th

Pagina 53

Appendix A. Miscellaneous A.3 Console cable pin assignment CAB-DB9DB9F-232-3 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 DB9F

Pagina 54

Appendix A. Miscellaneous A.6 SNMP RJ-45 pin assignment Pin Signal Description 1 TX+ Transmit (+)* 2 TX- Transmit (-)* 3 RX+ Receive (+)* 4 NC No

Pagina 55

Appendix A. Miscellaneous 59 A.8 SNMP Object Details Path=iso.org.dod.private.enterprise.ctc.fmux04.local Object Identifier Object Type stat Parame

Pagina 56 - Appendix A. Miscellaneous

Table of Contents ii 3.5.2 Define System Parameters ... 27 3.5.3 Di

Pagina 57

Appendix A. Miscellaneous 60 Object Identifier Object Type stat Parameters local_phone_configuration RW 0 - off 1 - on local_alarm_relay R

Pagina 59

Fiber Converter Series CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology

Pagina 60

Chapter 1: Introduction 7 Chapter 1. Introduction Thank you for choosing the FMUX04. If you would like to skip right to the installation and configura

Pagina 61

Chapter 1: Introduction 8 When configured for E1 operation, the 4 channels of the FMUX04 may use either BNC (75 Ohm unbalanced) or RJ-45 (120 Ohm bal

Pagina 62 - Fiber Converter Series

Chapter 1: Introduction 9 When the FMUX04 is ordered with optional Order Wire, a hardware card is installed inside the unit. The front panel's R