CTC Union SHDSL Especificaciones Pagina 61

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 120
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 60
60
FAS Data Data Data Data Data Data Data Data
01234567
831
Time Slot
64k 64k 64k 64k 64k 64k 64k 64k 64k 64k1408k
9 ~ 30
RULE
First Time Slot ? 31- Time Slot Number
First Time Slot ? 31- Time Slot Number
FAS
01234 16
31
Time Slot
64k 64k 64k 64k 64k 64k 64k896k
17 ~ 30
CAS
5 ~ 15
704k
RULE
First Time Slot ? 30 - Time Slot Number
First Time Slot ? 30 - Time Slot Number
Data Data Data Data Data Data Data Data Data Data Data
01234567
831
Time Slot
64k 64k 64k 64k 64k 64k 64k 64k 64k 64k1408k
9 ~ 30
Fractional E1
For fractional E1( FE1), the data rate is from 64k, N=1, to 1984k, N=31, according to the E1 frame.
If the E1 frame is PCM31(FAS) or PCM31C(FAS+CRC4), there are 1~31 available time slots for data use.
For example, if the data rate of SHDSL line is set to 512k, the time slot number is 8 and first time slot number
is 1. The frame is shown as below.
The First Time Slot setting of FAS and FAS+ CRC4 (PCM31 and PCM31C) must follow this rule:
Using E1 framing FAS+CAS or FAS+CAS+CRC4(PCM30 or PCM30C), the [FAS] will occupy Time Slot 0
and [CAS] will occupy Time Slot 16. There are only 30 Time Slots left for data. The data rate is 1920kbps
(30x64Kbps).
The First Time Slot setting of FAS+CAS and FAS+CAS+CRC4 (PCM30 and PCM30C) must to follow this
rule:
Unframed E1
Used data is inserted into all 32 channels (64Kbps x 32 = 2048Kpbs) of the E1 bit stream